2007
A frequency‐based approach to locate common structure for 2D‐3D intensity‐based registration of setup images in prostate radiotherapy
Munbodh R, Chen Z, Jaffray DA, Moseley DJ, Knisely JP, Duncan JS. A frequency‐based approach to locate common structure for 2D‐3D intensity‐based registration of setup images in prostate radiotherapy. Medical Physics 2007, 34: 3005-3017. PMID: 17822009, PMCID: PMC2796184, DOI: 10.1118/1.2745235.Peer-Reviewed Original Research
2003
Entropy-Based Dual-Portal-to-3-DCT Registration Incorporating Pixel Correlation
Bansal R, Staib LH, Chen Z, Rangarajan A, Knisely J, Nath R, Duncan JS. Entropy-Based Dual-Portal-to-3-DCT Registration Incorporating Pixel Correlation. IEEE Transactions On Medical Imaging 2003, 22: 29. PMID: 12703758, DOI: 10.1109/tmi.2002.806430.Peer-Reviewed Original ResearchConceptsRegistration frameworkImage dataMutual information-based registration algorithmRegistration parametersPortal imagesUltrasound image dataReal patient dataTomography image dataImage pixelsPixel correlationRegistration algorithmPatient setup verificationSegmentationPixel intensityMarkov random processInitial versionTransformation parametersAppropriate entropyImagesAlgorithmPatient dataFrameworkCT imagesLine processSetup verification
1999
A minimax entropy registration framework for patient setup verification in radiotherapy
Bansal R, Staib L, Chen Z, Rangarajan A, Knisely J, Nath R, Duncan J. A minimax entropy registration framework for patient setup verification in radiotherapy. Computer Assisted Surgery 1999, 4: 287-304. PMID: 10631372, DOI: 10.1002/(sici)1097-0150(1999)4:6<287::aid-igs1>3.0.co;2-9.Peer-Reviewed Original ResearchA Minimax Entropy Registration Framework for Patient Setup Verification in Radiotherapy
Bansal R, Staib L, Chen Z, Rangarajan A, Knisely J, Nath R, Duncan J. A Minimax Entropy Registration Framework for Patient Setup Verification in Radiotherapy. Computer Assisted Surgery 1999, 4: 287-304. DOI: 10.3109/10929089909148182.Peer-Reviewed Original ResearchEntropy-Based, Multiple-Portal-to-3DCT Registration for Prostate Radiotherapy Using Iteratively Estimated Segmentation
Bansal R, Staib L, Chen Z, Rangarajan A, Knisely J, Nath R, Duncan J. Entropy-Based, Multiple-Portal-to-3DCT Registration for Prostate Radiotherapy Using Iteratively Estimated Segmentation. Lecture Notes In Computer Science 1999, 1679: 567-578. DOI: 10.1007/10704282_61.Peer-Reviewed Original ResearchPatient setup verificationPortal imagesReal patient dataSingle portal imagePose parametersCT data setsRegistration frameworkRegistration parametersSetup verificationDifferent initializationsAlgorithmMultiple portalsIterative fashionData setsTransformation parametersAppropriate entropyImagesCT dataPatient dataVerificationNoise conditionsFrameworkSegmentationAccurate estimationInitialization
1998
A novel approach for the registration of 2D portal and 3D CT images for treatment setup verification in radiotherapy
Bansal R, Staib L, Chen Z, Rangarajan A, Knisely J, Nath R, Duncan J. A novel approach for the registration of 2D portal and 3D CT images for treatment setup verification in radiotherapy. Lecture Notes In Computer Science 1998, 1496: 1075-1086. DOI: 10.1007/bfb0056297.Peer-Reviewed Original ResearchRegistration parametersMulti-modality image registrationResolution imagesPortal imagesLow-resolution imagesMutual information metricHigh-resolution imagesImage registrationCT data setsSetup verificationLow contrastInformation metricData setsDifficult problemLow resolutionNovel approachImagesAlgorithmCT dataRegistrationCT imagesVerificationEntropy algorithmSegmentionMetrics