2024
Thursday, July 11, 20244:00 PM - 5:00 PM PP01 Presentation Time: 4:00 PM Investigating Shielding as a Dose-Shaping Tool in Flattening Distal Dose Profiles for Single-Channel Vaginal Cylinders
Tien C, Mullane S, Draeger E, Rivard M, Chen Z. Thursday, July 11, 20244:00 PM - 5:00 PM PP01 Presentation Time: 4:00 PM Investigating Shielding as a Dose-Shaping Tool in Flattening Distal Dose Profiles for Single-Channel Vaginal Cylinders. Brachytherapy 2024, 23: s26-s27. DOI: 10.1016/j.brachy.2024.08.020.Peer-Reviewed Original ResearchModel-based dose calculation algorithmsSingle-channel vaginal cylinderDose profilesDose distributionVaginal cylinderCentral axisCustomized shieldingRegions of high doseAnisotropic dose distributionUniform dose profileDose calculation algorithmWater-equivalent materialDose calculation methodMonte CarloIr-192 seedsDose gridIr-192MC simulationsRelative doseShielding materialsCalculation algorithmSource transitionDose optimizationLateral radiusShielding
2012
SU‐E‐T‐289: On the Use of a Diode Array for the Commissioning of Dynamically‐Wedged Asymmetric Fields Generated by Varian EDW's in the Pinnacle Treatment Planning System
Ahmad M, Liu W, Deng J, Nguyen K, Wu D, Chen Z, Moran M, Nath R. SU‐E‐T‐289: On the Use of a Diode Array for the Commissioning of Dynamically‐Wedged Asymmetric Fields Generated by Varian EDW's in the Pinnacle Treatment Planning System. Medical Physics 2012, 39: 3770-3770. PMID: 28517261, DOI: 10.1118/1.4735357.Peer-Reviewed Original ResearchArray systemMonte Carlo code BEAMnrcEnhanced dynamic wedgeDiode arrayCylindrical chamberSolid waterDose profilesCentral axisVirtual waterAcceptable accuracyPinnacle3 treatment planning systemBeamDiode array systemOutput factorsWedge angleSegmented treatment tablesAsymmetric fieldsSimulationsConvolution calculationMC predictionWater phantomWaterAxis dose profilesCentral axis percentage depth dosesPercentage depth doses
2006
Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams
Ahmad M, Chen Z, Song H, Deng J, Nath R. Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams. Radiation Protection Dosimetry 2006, 120: 159-162. PMID: 16644932, DOI: 10.1093/rpd/ncj006.Peer-Reviewed Original ResearchConceptsEDR-2 filmsElectron beamRelative dosimetryHigh-energy photonsClinical radiation dosimetryDose profilesPhotonsRadiation dosimetryBeamDose distributionRadiographic filmsSensitometric studyFilmsDosimetryTreatment planning techniquesElectronsDiodesSymmetryKVFlatnessPlanning techniquesDistribution